FCR Prima T2 Veterinary Set

Description

Advantages of the CR System:

In CR, cassettes with phosphor plates are used instead of cassettes with x-ray films. The image formed in the phosphor plates is transferred to the computer by digital scanners. In the examinations made on the computer screen, the image settings are made again as desired and the phenomenon is observed in the most clear way. Images can be stored for years for follow-up. In addition, the patient is protected from the troubles of carrying and storing the X-ray film, and if desired, a CD or DVD can be given or the image can be sent by e-mail.
Since there is no need for a bath device, bath solution and dark room in CR, the film is printed without the use of environmentally hazardous chemicals containing heavy metals. Since no time is spent for the bathroom in the dark room, faster results are obtained. Since the captured image is transferred to the computer screen, various adjustments are made to facilitate the diagnosis and the best result is obtained without the need for repetition of shooting. Since all X-rays taken with computerized x-rays are transferred to digital environment and stored for years, the follow-up of the patient and the case is made easily.
Patients who are filmed will be exposed to 50-60% less radiation. In addition, there is no need to repeat shots in errors caused by dosing.
Consultation can be quick, as the images are easily sent to another physician.
Special measurements required for hip dysplasia, heart enlargement, size of broken parts, kidney dimensions and orthopedic operations can be made without error.
Will be able to use the place reserved for the dark room in the physician clinic for other purposes

Advantages of FUJIFILM CR System:

Image Intelligence ™, developed by FUJIFILM and patented, increases the contrast and clarity of the entire image without any risk of loss of image details. With Image Intelligence ™, the phenomenon is optimized for the eye to perceive. Thus, the physician can make the correct diagnosis easier. Thanks to its compact structure, it is only 54x56x39cm in size, 39kg in weight and occupies 0.30m² on the desktop. Prima, which is the most compact and lightest reader compared to other devices on the market, is the fastest CR in the world with 73 processing capacity per hour.
The time required to install IP is 49 seconds, screen opening time 23 seconds, print time 155 seconds (35×43 film).
Scanners read on curved surfaces better than on flat surfaces. For this reason, FUJIFILM produces the plates in a flexible structure and places them in the cassette by creating a fold. Thus, a better image is presented.
In FUJIFILM, cassette and plate are two separate parts. If the cassette is broken during use, only the cassette is changed, if the plate is broken, only the plate is changed. Most of the cassette and the plates creme sold in Turkey are in one piece.
FUJIFILM CRs have a high performance DQE (Detectable Quantum Efficiency) value. In other words, it receives the beam at a higher rate. Therefore, high beam performance is obtained by using low beam. Thus, patients and physicians are exposed to less radiation.
During the shooting, the cassettes may be damaged by contacting with body fluids such as blood and urine. To prevent this, the cassettes are placed in special PVC coverings. And shooting is done this way. Thus, contact of the phosphor plates with body fluids is prevented and the life of the cassettes is extended.
Thanks to its high technology, FUJIFILM detects and prevents problems in the device before they occur. Thus, FUJIFILM offers longer-lasting devices to the user. It offers the opportunity to work in 5 different film sizes.
Up to 200,000 images can be archived in FUJIFILM CR.
With the simplified DICOM program, data management can be done quickly and easily.
If desired, the film can be printed on the DRY system. FUJIFILM’s patented Image Intelligence ™ feature, which provides superior image quality, consists of 3 functions.

MFP (Multi-Frequency Processing): It increases the contrast of the entire diagnostic area, except for the interferences that degrade the image quality.

FNC (Flexible Noise Control): It prevents the formation of noise that degrades the image quality, while preventing condensation in the image for a good image.

GPR (Grid Pattern Removal): It prevents the formation of a fixed grid that disrupts the image quality and provides easy diagnosis and prevents misdiagnosis.

TOP